Friday, October 9, 2009

Hemmerhoid Surgery Cost

should look like the balancer in practice?

I have decided, as the individual Balancersystem
modules (one per cell) to gestalten.Das
makes the system universally used. For now, I'll make the arrangements
well with a quad-OP to simply
to be flexible, and the thresholds at any time modify
can.
The target I have not (yet?) The use of ICs in
Seiko Auge.Die but must be ordered with the
appropriate thresholds, and
lies the problem. (.! VE = 3000ST)
is the first, if all values 100% fit

There would be another possibility:
a "PIC", which is a tiny "complete computer"
now are the "penny items
Overall a single IC from about 1 euro ....... evaluate
Three voltage limits as
is not a problem, look I just need
which types have been running with 2V, and whether I
the necessary programming tools etc. have this.
"Looking down time!" With a view to "Mindaugas"
one matching found, but for the
I do not have the necessary equipment. (ATtiny25)
the 12F683 or the 12F675 would pinch
also appropriate because we would have even
similar programs in the drawer, but here
missing a reference voltage. A
LM 4041CFTA of Zetex would be useful because
(ca.50cent 1.24V)
The problem is the low supply voltage
. the 12F ....
run from 2V Attiny from 1.8
many voltage references only
from 3V. The 4041 is 2-pole
go and have a few uA
accurate to 0.5%. Thats IT!
but if I already have a need
voltage reference,
then the PIC is of little
because I need the 4-bin-OP
only four (bzw5) Resistors
more and no money is saved.
A series of
(+) 1k5, 660R = 2x330R, 33R, 1k1; (gnd)
is quite accurate to thresholds at 3.6 V
(Dub), 3.5 V (Balancer)
and 2.2 V (Untersp.); a little high, about 3%,
would fit with 1.2 V ref, but something
hintrimmen, it fits perfectly.

from electrical and mechanical reasons, I think
best to mount the regulator to the battery contacts
or in their place, and the positive terminal
run as a short cable.
the board to screw directly on the battery
I consider dangerous because of the high current
me for any vias
too high and therefore dangerous appears.

Because of the modular structure of each
module is the same. the connection between the modules
should be made by the housing and the messages
are designed as a loop, so that an interruption
immediately noticeable.

Scheduled Messages:
1.Unterspannung any cell
2.Überspannung any cell
3.Irgendein Balancer works
or work all the balancing.

under and over voltage, I'll summarize
, since it can be safely distinguished
, whether loaded or grad
is unloaded.

Whether any balancer has been working soooo
is probably not important, but if all
work, then charging
be ended, which was lacking any
"time factor", since the balancer overclock, yes.

If I take ZB12-pin cable,
is the number of reports not the problem.
rather have the space on the modules. The well-known
Goodrum-fencers
system because a few wicked disadvantages
covered but only when used on "big"
battery weight.
For the actual use of small batteries
(bicycles, etc.)
the system is great! I want to make the system
certainly not bad, but
with charging currents of 20A and more
it is easily overwhelmed.
There was even thought of before!
particular, the surge
monitoring is essential
when the charge current higher than the maximum
Balancerstromstärke.
(if sometimes a cell will "die")
The state "all the balancing work" must
as a switching contact to the Available, and
should stop charging by the charger off

now is whether any balancer is already working, the
does not seem quite so important.
other hand, that would be a signal to reduce the charge current
, otherwise burned
energy in the balancers is

How could the individual modules
access to individual cells, for example, the voltage measured
???????
issue or at least,
reports which cell disorder?

This could go if you control lines
binary coded controls. (Not yet tested)
with six lines +
mass could be either a specific address module
(voltage measurement)
and the number of the module to receive
disorder. up to 63 cells! The
goes both ways!
If the number matches the number of the module
a relay
the voltage of the cell to two leads. Reports
a module failure, it feeds on its own
one of its number, while giving out his
voltage. If no number is fed
is the number that is 0, could form the total voltage appears
werden.Dies number can be shown without much effort

right here, of course, the display only
a single, or the first message, but that does
already times further.
Tightening several relays simultaneously is simply to prevent
, hen you relay with four changeover takes
.
and supplies (12V and GND)
from both ends and feeds
forward to opener. Attracts a
relay, no other more
attract
If you want more is really complicated.
The cores of the cable is no problem and there can

prefabricated cables are plugged in easily.
would in this case the modules
be coded accordingly.
eg diode or jumper
if enough space.
There comes together for so many parts of
.
a reference voltage source
a four-times-OP
four resistors for the voltage divider
a small MOSFET + diode + resistor
per signal loop
an optocoupler + about 8 diodes for
the coded bibs,
and if you want to have even the
voltage output
would probably still a relay
+ several AND gates to
This is England! But in SMD technology
should do the trick. The load resistance
and the ribbon cable connector are still there
.............................

The edition number is probably feasible, but the meter is
sure
a standalone device. But
to control the modules from,
goes to the all cases.
is then at least found
which cell caused the alarm,
and excitement as well as the number of cell
be displayed.
(additional cost per module for about 3 €)
and spaghetti wiring "
with thin lines to the measurement module.

I want there is also a voltmeter
install and build the control panel separately.
A key 0 (zero) is a button for "UP"
possibly one for "Down" a
seven-segment display for the number
and Diitalvoltmeter.Bei 0 the
displayed total voltage, or
automatically in case of failure of a module
whose value gezeigt.Wie already said, only
The first displays correctly,
but that's something.
Then you have to search for bugs anyway, so the operation of

battery room.

people, tell me your opinion!
Constructive criticism is always welcome

mfG
Franz After

0 comments:

Post a Comment